Frequently Asked Questions
We solve your most common doubts about grounding systems, lightning rods and power quality.
1What is the warranty period for our products?
| Physical Earth Systems | 20 years |
| KDA Lightning Arrester Systems | 20 years |
| Piezo tips | 20 years |
| Transient Suppressors | 5 years |
| Telcos | 1 year |
| Capacitor banks | 2 years |
| UPS's | 2 years |
2Can I purchase a lightning rod tip separately?
If possible. The lightning rods with piezoelectric technology, as well as the tips
solid, crown dipole and franklin can be purchased separately. Our line of
Magneto-active lightning arresters or KDA are only supplied in Kit with a system of
efficient soil, as well as a soil improving compound that guarantees low
impedance.
3Do Total Ground teams have Certificates?
Our teams can have certificates ANCE, LAPEM and UL.
Consult with your account executive the certificates that apply for each product.
4Where can I purchase the products?
We have a wide network of more than 220 points of sale with various
distributors throughout the national territory, as well as in Latin America,
United States and Canada.
5Why should the surge suppressor be installed? parallel voltage and why should thermal switches be placed?
Surge suppressors are placed in parallel as they suppress voltage spikes. About
the topic you can consult the NOM 001 HEADQUARTERS Art. 285 and the NMX J
549 ANCE section 4.4.3; should be placed on the side of the load or board
Protect no more than 3 meters of cable.
The thermal switch must be added so that in the event of a suppressor failure the equipment are not exposed to damage; Additionally, it facilitates the maintenance of the suppressor.
The thermal switch must be added so that in the event of a suppressor failure the equipment are not exposed to damage; Additionally, it facilitates the maintenance of the suppressor.
6How do I know if my electrical installation is correct and guarantee the good functioning and long useful life of the equipment?
The ideal is to carry out preventive and/or corrective maintenance that includes tests and
studies of Grounding, Lightning Rod, Power Quality and
Continuity, with adherence to NOM 001 HEADQUARTERS 2012 and NOM 022
STPS, among others. Some specific points:
- Check the physical condition of your ground system.
- Perform a resistance measurement and verify if it complies with regulations applicable in your area.
- Check the status of your electrical network in search of anomalies or cables burned.
- Conduct a power quality study to see electrical disturbances in your network and make the best decisions.
7How to get my volume in a survey?
As a first part, you must identify the needs, prioritizing the following:
- Electrical circuits.
- Grounding System for transformer or main board.
- Grounding System for IT equipment.
- Determine the level of incidence of annual atmospheric discharges based on with NMX-J-549-ANCE or other regulations in force in each region.
- Determine the need for Transient Surge Suppressors.
- Verify existence of equipotential bonding between the different Systems of Grounding of the site.
- Request Energy Quality studies to identify Bank needs of Capacitors, Harmonic Filters, UPS, Luminaires, among others.
- Perform resistance measurements.
- Take out wiring paths in meters for equipotential bonding.
- Ask the site supervisor if there are interfering pipes or wiring on the marked path.
- Based on needs, verify wiring paths on site to obtain the volumetry of the necessary materials.
8What Standards do Total Ground Products comply with?
Our products, together with good installation, can meet the
following Norms, Standards and Recommendations:
Nationals:
Note: NOM is Mandatory; NMX is
Volunteer.
- NOM-001-SEDE (current) — Electrical Installations (Use).
- NOM-022-STPS (current) — Static Electricity in Work Centers.
- NMX-J-549-ANCE (current) — Protection System vs. Electrical Storms.
- NFPA 780 — Standard for the Installation of Lightning Protection Systems.
- EIA/TIA 607 — Grounding and Bonding Requirements for Telecommunications.
- EIA/TIA 942 — Telecommunication Infrastructure Standard for Data Centers.
- IEEE 142 — Grounding of Industrial and Commercial Power Systems.
- IEEE 1100—Powering and Grounding Electronic Equipment.
- ICREA TIERS
9What is the life time of the Total electrodes? Ground?
Our magnetoactive electrodes have a 20 year warranty. If
suggests evaluating the type of terrain to verify if it is more appropriate to use steel
stainless or copper.
10Does a capacitor bank help me reduce my consumption electric?
By correcting the power factor, you put the voltage and current in phase, which
It means that electrical energy is better used. This way, charges are eliminated.
by power factor and it is possible to qualify for bonuses for a good
use of the electrical network. Does not apply to single-phase installations and
biphasic.
11What information do I need to get a quote? lightning rod?
For the correct specification of a lightning rod we will ask you for the following:
- Geographic location of the site where you want to install the lightning rod.
- Do you have a plan with cuts? Or, heights of the building and surroundings (an aerial view of Google Maps is also useful), delimiting the area to protect.
- Type of property: school, hotel, house, hospital, factory, etc.
12What percentage of copper do the electrodes have? Total Ground?
To manufacture our electrodes, we use 99.9% pure copper;
the rest is residual phosphorus that by nature binds to copper, reduced to a minimum
percentage.
13What guarantees are there and what is the processing process like? for validation?
By purchasing a Total Ground brand product you can receive its guarantee. It's just
You need to send us:
- A photographic memory of the installation and measurements, verifying that the Installation was carried out in accordance with our manuals and the regulatory framework applicable.
- Copy of your invoice.
14What information do I need to send so that you can support me? quote a physical ground system?
The most important thing is to know the application:
- Power system: board capacity or voltage, or transformer if they have it.
- Logical Zero (communications racks / sites): capacity of UPS / racks, or number of computers and equipment to be landed.
- Masses (barns, tanks, towers, etc.): location, dimensions and floor plan.
15How do I register for the webinars (courses)?
Steps to access the course:
- Enter the link of the course in which you are interested.
- Enter corresponding data (full name and email).
- Accept terms and conditions in the same box.
- Click on "Register Now".
- You will receive a reminder email and soon another to access directly to the course.
16How do lightning rods work?
Lightning rods basically have a tip, a drop cable and a system of
physical land. Its main function is to capture the lightning and take it to discharge in a
safe place, avoiding damage to people, animals, buildings or equipment.
The tip generates an ascending leader that makes a link between the earth and the cloud, generating the return discharge. The tip receives the discharge, the driver transports the current to the grounding electrode, and it dissipates it — that's why the importance of having lower resistance to 10 ohms and a capacity of dissipation given by the contact area of the buried element.
The tip generates an ascending leader that makes a link between the earth and the cloud, generating the return discharge. The tip receives the discharge, the driver transports the current to the grounding electrode, and it dissipates it — that's why the importance of having lower resistance to 10 ohms and a capacity of dissipation given by the contact area of the buried element.
17Can I put solder instead of connectors mechanics?
The design of our electrodes features studs for mechanical terminals or
punctureable However, you can opt for soldering with tin or using the innovative
Tech-Fussion exothermic welding.
Soldering ensures superior conductivity and reliable sealing for joints permanent. Mechanical connectors offer advantages where resistance to Vibrations and ease of maintenance are key. With Safe-Connector and Tech-Fussion, you carry your connections to the next level.
Soldering ensures superior conductivity and reliable sealing for joints permanent. Mechanical connectors offer advantages where resistance to Vibrations and ease of maintenance are key. With Safe-Connector and Tech-Fussion, you carry your connections to the next level.
18Why can Total systems be guaranteed Ground for so long?
Being a system that has a dual-function conditioner—guaranteeing the
resistivity at low levels and take care of the useful life of the copper—this allows us
guarantee our systems for 20 years.
19Based on what determine the calibers and models of the selection table that they provide us?
Depending on the amount of current that the electrode can dissipate.
20What is the difference between a rod and an electrode? tubular delta?
There are numerous differences; We expose some:
- The rods have only an external copper film; Total electrodes Ground are 99.9% copper.
- The contact area of our electrodes is always greater than that of a rod, since they have a larger diameter.
- The installation of the Total Ground electrodes is very simple, not so with the rods.
- The useful life of the rods can be very short compared to a Total electrode Ground.
21How should a ground system or lightning rod?
Ground system: additional to the composite bag and in some
sometimes the coupler, you will require connectors (dogs and shoes), a register for
review and measure the soil periodically, Antiox to give a long useful life to your
connections, in addition to cable and conduit.
Lightning rod: additional to the requirements of the ground system, you will need to determine the implements to set the tip — it can be from just one base, or a base and a mast, and in necessary cases a tower so that the tip reaches the necessary height.
Lightning rod: additional to the requirements of the ground system, you will need to determine the implements to set the tip — it can be from just one base, or a base and a mast, and in necessary cases a tower so that the tip reaches the necessary height.
22How can I do a sizing with more than one application to land?
First, the applications to be protected must be separated taking into account the
operating characteristics of each one. Depending on the distances you can
perform protection in two ways:
- Designate a bar and ground system for each application.
- Use a general ground system and separate the different applications by means of impedance couplers, making a sum of the loads to get the electrode size.
23How to take into account risk levels in suppressors?
The NMX-J-549 gives us the recommended bases according to parameters such as
incidence of lightning and the type of site where the installation will take place;
additionally, the short circuit current data indicated in the
NOM-001-SEDE (updated) Art. 285-6. Remember that the loads
Inductive are involved in the generation of transients.
24What is the difference between Total Ground and others technologies?
- Elderly dissipation capacity of the current.
- High performance magnetoactive electrodes.
- Greater contact area with the ground, helping to dissipate current and heat heat.
- RCL filter to filter low frequencies.
- Personalized technical support and accompaniment.
- Experience of more than 25 years in the market.
- Easy installation.
- Industry-leading warranties.